Add to Cart
Performance description and characteristics:
1,Feed system
It is composed of screw pump and feed pipe and valve.
The screw pump adopts frequency conversion speed regulation to effectively control the feed quantity. The main part of the pipeline valve is SUS304 stainless steel, and it is clean and sanitary
2,Medium circulation system
It is composed of blower, draft fan, muffler, air regulating butterfly valve and wind pipe
Draft fan and blower are high quality manufacturers supply, cooperation for many years, quality is stable; the blower for SUS304 stainless steel, to ensure clean air; fan with a silencer, effectively reduce the noise. The system volume, wind pressure, wind speed, is the key, based on years of experience, is now mature.
3,Air heating and cleaning system
It consists of early, medium and high temperature HEPA filters, fans, steam radiators, electric heaters, etc.
The heat source is a steam radiator and an electric heater. The material is made of stainless steel pipes and stainless steel fins. The utility model not only ensures the cleanness of the air inlet system, but also has high thermal efficiency and can guarantee the output heat
4,Drying tower system
It is composed of a dry main tower, a hot air distributor, an atomizer, an observation manhole, a tower lighting device, a pneumatic hammer, a lower bin, a cylinder body and a cone jacket, and a cooling system
This system is the core system
1, combined with the test experience, we in the design process of the main tower of the main tower: adjust the straight cylinder height to diameter ratio, adjusted by 0.9:1 routine to about 1.1:1; prolong the retention time of the material, the drying effect is ensured. The adjustment of the taper cone tower, consists of a conventional 60 degree angle adjustment to 54 degrees, fully considering the smooth material in the cone when feeding.
2, the atomizer atomizer using frequency converter to adjust the speed to achieve the best effect. The base will reduce the atomizing atomizer, the atomizing disk atomizer and increase the distance, the droplets in the air can not be returned under the spinning top, in order to ensure the normal operation of the system.
3, design a set of Taneiduo lighting devices and 1 doors, manholes.
4, hot air vortex shell tower by accelerating structure, the hot air in the tower when pressed material effectively, orderly and swirl decreased. Hot air distributor with the characteristics and requirements of the technology, do both sides distributor the wind guiding mechanism, and can adjust the angle, in order to control the hot air into the tower when the tangential angle.
5, the main tower design of jacket cooling cooling system: to avoid the main tower body wall temperature is too high and the receiving effect of the adsorption tower in the cone wall material by high temperature and coking softening phenomenon, ensure the quality of the materials.
5,Product collection system
The utility model is composed of a cyclone separator and a water film dust collector
6,Cold desiccant charging system
It is composed of air filter, freezing dehumidifier, cleaning pipe and so on. The system sends the fresh air to the clean area and collects the cooling air after the filtered fresh air passes through the refrigeration dehumidifier.
7,Other auxiliary system
Are well-known manufacturers of supply, reliable performance; some pipes take into account a certain angle design, the use of suppression stainless steel pipe, to avoid the end material, blocking material, and local resistance is too large, affecting the phenomenon of material delivery.
type | LPG | |||||||
5 | 25 | 50 | 100 | 150 | 200-3000 | |||
Inlet temperature | ≤ 350°C | |||||||
Outlet temperature | 80-90°C | |||||||
evaporate capacity (kg/h) | 5 | 25 | 50 | 100 | 150 | 200-3000 | ||
driving type | compressed air drive | mechanical drive | ||||||
Rotate speed | 25000 | 22000 | 21500 | 18000 | 18000 | 15000 | ||
diameter of atomizer tray (mm) | 50 | 120 | 120 | 120 | 150 | 180-340 | ||
heating source | electricity | electricity | electricity +steam+fuel oil+coal gas | electricity +steam | electricity +steam+fuel oil+coal gas | To be solved by users | ||
Electric-heating power (kw) | 9 | 45 | 60 | 81 | 99 | |||
Dried powder recovery rate (%) | ≥ 95 | ≥ 95 | ≥ 95 | ≥ 95 | ≥ 95 | ≥ 95 | ||
Installation size | A(mm) | 1000 | 1290 | 1730 | 2500 | 2800 | according to practical needs | |
B(mm) | 2100 | 3410 | 4245 | 5300 | 6000 | |||
C(mm) | 2300 | 4260 | 4645 | 6000 | 6700 | |||
φ D(mm) | 1060 | 1800 | 2133 | 2560 | 2860 | |||
E1(mm) | 1050 | 1200 | 1640 | 2100 | 2180 | |||
E2(mm) | 1050 | 1200 | 1640 | 2100 | 2180 | |||
F(mm) | 750 | 1000 | 1250 | 1750 | 1970 | |||
G(mm) | 530 | 1700 | 1750 | 1930 | 2080 | |||
H(mm) | 530 | 1300 | 1800 | 2600 | 3050 | |||
I(mm) | 530 | 1550 | 1600 | 1780 | 1960 |